NE7-CO-H Range (Hydrogen Immune)

Special 4-Electrode Industrial Carbon Monoxide (CO) Sensors

General Description:

The NE7-CO-H range are two new electrochemical gas sensors with 4 electrodes, for the detection and monitoring of Carbon monoxide (CO). The sensor is particularly suitable for applications where zero sensitivity to Hydrogen is essential, such as Flue Gas Analysers and Anti-smoking breath-testers. The performance of the sensor is designed to conform with EN 50379 in Flue Gas Analysers. These sensors require a special circuit.

Nemoto's porous electrode technology enables accurate gas detection with high sensitivity. The mechanical design of the sensor gives optimum gas diffusion characteristics, and the hermetically sealed enclosure prevents costly electrolyte leakage.

2 Options are available: NE7-CO-H (0-1000 ppm range)

                                       NE7-CO-H10000 (0-10,000 ppm range)

Specifications:

NE7-CO-H

Detectable Gas:

Detection range:

Maximum overload:

Output current:

Zero Offset (20°C)

Reproducibility:

Output drift

Response time (90%):

Temp. depend. in air:

Expected lifetime:

Carbon Monoxide (CO)

0 – 1000 ppm

2000 ppm

100+/- 20nA/ppm

<+/- 5 ppm equivalent

+/- 1%

less than 5% / Year

< 35 seconds

-3 to +15 ppm

>5 years

NE7-CO-H10000

Carbon Monoxide (CO)

0 – 10000 ppm

20000 ppm

15+/- 4nA/ppm

TBA

+/- 2%

less than 5% / Year

< 40 seconds

-10 to +50 ppm

>5 years

NE7-CO-H DATASHEET NE7-CO-H10000 DATASHEET

Operating Conditions:

Operating temperature:

Humidity range:

Pressure:

Recommended resistor:

Bias voltage:

-20 +50 degrees C

15 – 90% RH

0.9 – 1.1 atm

10 ohms

Not required

-20 +50 degrees C

15 – 90% RH

0.9 – 1.1 atm

10 ohms

Not required

MANUAL (COVERS BOTH DEVICES)